HOME
ABOUT US
REFERENCES
REPRESENTATIONS
CONTACT US
TÜRKÇE
Engineering and Technical Education
PHYSICS
ELECTRONICS
COMMUNICATIONS
ELECTRICITY
ENERGY
MECHATRONICS, AUTOMATION & COMPUMECHATRONICS
MECHANICS
FLUID MECHANICS
THERMODYNAMICS & THERMOTECHNICS
PROCESS CONTROL
CHEMICAL ENGINEERING
FOOD & WATER TECHNOLOGIES
ENVIRONMENT
BIOMEDICAL ENGINEERING
Physics, Chemical, Biology Education
OPTIKASCIENCE
DATA HARVEST
ERLER-ZIMMER
Maths Education
OPTIKASCIENCE
Section 10 – On-Line Science
1. OPTIKASCIENCE
1.1. Section 01 - Kits
1.1.1. Physics Laboratory Sets
1.1.2. Basic Kits
1.1.3. Advanced Kits
1.2. Section 02 - Physics
1.2.1. Statics of solids
1.2.2. Dynamics
1.2.3. Translational motion
1.2.4. Rotational motion
1.2.5. Oscillatory motion
1.2.6. Inertia- Collisions - Two-dimension motion
1.2.7. Liquids
1.2.8. Gases and vacuum
1.2.9. Wave's propagation
1.2.10. Sound Waves
1.2.11. Molecular aspect of matter
1.2.12. Temperature and Heat
1.2.13. Geometrical Optics
1.2.14. Wave Optics
1.2.15. Optical Benches
1.2.16. Electrostatics
1.2.17. Electrical conduction
1.2.18. Magnetism and electromagnetism
1.2.19. Atomic Physics
1.3. Section 03 - Technique and Energy
1.3.1. Energy conversions
1.3.2. Renewable energies
1.4. Section 04 - Microscopy
1.4.1. On-field microscopy kits
1.4.2. Biological microscopes
1.4.3. Stereomicroscopes
1.4.4. Multimedia system
1.4.5. Microscopy accessories
1.4.6. Optical magnifiers
1.4.7. Prepared slides for microscopy
1.5. Section 05 - Biology
1.5.1. Botany
1.5.2. Zoology
1.5.3. Experiments on human beings
1.5.4. Human anatomy and DNA models
1.6. Section 06 - Ecology
1.6.1. Kit for environmental analysis
1.6.2. Items for sample's collection
1.6.3. Stations for the detection of air pollution
1.6.4. Digital instruments
1.7. Section 07 - Meterology
1.7.1. Instruments and weather stations
1.8. Section 08 - Astronomy and Earth Science
1.8.1. Rocks, fossils and minerals
1.8.2. Geological models
1.8.3. The Earth and the solar system
1.9. Section 09 – Chemistry
1.9.1. Periodic table of elements
1.9.2. Molecular models and atomic models
1.9.3. PH-meters
1.9.4. Refractometry
1.9.5. Polarimetry
1.9.6. Spectroscopy
1.9.7. Electrology
1.10. Section 10 – On-Line Science
1.10.1. Interfaces
1.10.2. MBL Sensors
1.10.3. USB Sensor
1.11. Section 11 – Drawing and Mathematics
1.11.1. Drawing
1.11.2. Enumeration
1.11.3. Logics
1.11.4. Fractions and percentages
1.11.5. Geometry
1.11.6. Mathematics on magnetic blackboard
1.12. Section 12 – Measurement Instruments
1.12.1. Lengths and angles
1.12.2. Volumes/Time intervals
1.12.3. Temperature
1.12.4. Density/Forces, weights and masses
1.12.5. Electrical devices
1.13. Section 13 – Lab Tools
1.13.1. Items and instruments
1.13.2. Electrical power sources
2. DATA HARVEST
2.1. Data Logging
2.1.1. Data Loggers
2.1.1.1. Data Logging Range
2.1.2. Sensors
2.1.2.1. Sensor Range
2.1.3. Apps
2.1.3.1. Cross-platform software
2.1.4. Accesories
2.1.4.1. All Accessories
2.2. Dynamics
2.2.1. Dynamics System
2.2.2. Software
2.2.2.1. Cross-platform software
2.2.3. Accessories
2.2.3.1. All Accessories
2.3. Teaching
2.3.1. Teaching Packs
2.3.2. Teaching Metarials
2.4. More Science
2.4.1. Smart Microscopes
2.4.2. Genecon Hand-Held Dynamo
2.4.3. Renewable Energy
2.5. Product Brochures
2.5.1. Primary Teaching Brochure
2.5.2. Secondary Teaching Brochure
3. ERLER-ZIMMER
3.1. Anatomical Models
3.1.1. Skeleton Models
3.1.1.1. Pelvises
3.1.1.2. Limbs
3.1.1.3. Full Body
3.1.1.4. Skulls
3.1.1.5. Spines
3.1.1.6. Bones
3.1.2. Organs & Structures
3.1.2.1. Respiratory System
3.1.2.2. Brain & Nerves
3.1.2.3. Urinary System
3.1.2.4. Skin-Hair-Nail
3.1.2.5. Head Models
3.1.2.6. Circulatory System - Blood Vessels
3.1.2.7. Circulatory System - Hearts
3.1.2.8. Circulatory System - Circulation
3.1.2.9. Liver
3.1.2.10. Muscular Models
3.1.2.11. Kidneys
3.1.2.12. Ears
3.1.2.13. Torsos
3.1.2.14. Digestive System
3.1.2.15. Teeth
3.2. 3D Anatomy Series
3.3. Medical Simulators
3.3.1. Auscultation
3.3.2. Endoscopy
3.3.3. Gynaecology
3.3.4. Skin Suture
3.3.5. Injection
3.3.6. Nursing
3.3.6.1. Chronic Wounds
3.3.6.2. Diabetes
3.3.6.3. Catheterisation
3.3.6.4. Nursing Dolls - Baby & Child Dolls
3.3.6.5. Nursing Dolls - Adult Dolls
3.3.6.6. Stoma Care
3.3.7. Cancer Prevention
3.3.8. Emergency
3.3.8.1. Airway
3.3.8.2. CPR - Baby & Child Dolls
3.3.8.3. CPR - Adult Dolls
3.3.8.4. All Dolls - Baby & Child Dolls
3.3.8.5. All Dolls - Adult Dolls
3.3.8.6. Rescue
3.3.8.7. Thorax
3.3.8.8. Trauma Simulation
3.3.9. X-RAY / CT
3.3.10. Pregnancy & Birth
3.3.11. Ultrasound
9001 ScienceCube Pro
• It can be used as a stand-alone: the interface can be used without a PC connection.• Easy to use and portable.• It doesn’t need any special card or driver. Sensors are identified automatically.• Thanks to the LCD graphic display, you are able to read easily the collected data.• Different languages are available.• The firmware is constantly updated and implemented. ScienceCube Pro will update itself to be able to interface with the new sensors. Technical data Dimensions: 160x90x25 mm Display: 128×64 ampio graphic mono screen Data management: it is able to collect up to...
9019 Accelerometer 5g
Range:– 47 m/s2 ~ + 47 m/s2Best resolution:-19.6 m/s2 ~+19.6 m/s2Resolution:0.038 m/s2Frequency response:0 Hz ~ 100 Hz *Requires interface code cod. 9001 or 9107...
9066 USB distance sensor
Range: 0 ,16 ~ 6 m (Max. 10m)Resolution: ±1,5 mmMeasurement principle: SonarField of view: Conical, approximately 15°Sampling frequency: Max. 100 misure/s...
9107 Free Linker (wireless)
Technical data Input port: 4 channels (analog and digital) Network: Wireless bluetooth (RF 2.4GHz) / USB 2.0 Sampling rate: Max 10 kHz / 1 CH Resolution: 12bit ADC Battery: Li – polymer 1100mAh Charge: USB port (MAX. 500mA @5VDC) ...
9020 Accelerometer 25g
Range:– 245 m/s2 ~ + 245 m/s2Best resolution:-98 m/s2 ~ +98 m/s2Resolution:0.2 m/s2Frequency response:0 Hz ~ 100 Hz *Requires interface code cod. 9001 or 9107...
9068 USB force sensor
Range:±10N ~ ±80NResolution:±0,0056 ~ ±0,056Type of sensor:extensometric...
9072 USB light sensor
Range:0 ~15000 LuxResolution:Depending on sensivitySensitivity:Low: 0 ~ 15000 LuxAverge: 0 ~ 6000 LuxHigh: 0 ~ 600 LuxSpectrum range:330 nm ~ 720 nmWavelength at the maximum sensitivity:580 nm....
9021 Barometer
Range:0 hPa ~ 2068 hPaResolution:0.6 hPa *Requires interface code cod. 9001 or 9107...
9085 USB temperature sensor
Range:-25°C ~ +125°CResolution:± 0,1°CType of sensor:ThermistorProtected by stainless steelResponse time:10s (90%)Chemical resistance:15 minutes (1M HCl)...
9022 CO2 gas sensor
Range:0 ppm ~ 5000 ppm (0 ~ 0.5%)Resolution:2.44 ppmAccuracy (a pressione standard 1 Atm):±100 ppm (0 ppm ~ 1000 ppm)±10% (1000 ppm ~ 5000 ppm) *Requires interface code cod. 9001 or 9107...
9023 Conductivity probe
Range_1: 0 ~200 mS/cm (0 ~100 mg/L TDS)Range_2: 0 ~2000 mS/cm (0 ~1000 mg/L TDS)Range_3: 0 ~20000 mS/cm (0 ~10000 mg/L TDS) Resolution:Range_1: 0.1 mS/cm (0.05 mg/L TDS)Range_2: 1 mS/cm (0.5 mg/L TDS)Range_3: 10 mS/cm (5 mg/L TDS) *Requires interface code cod. 9001 or 9107...
9025 Colorimeter (II)
Range:10 ~ 90% TResolution:0.035 TWavelength:430 nm, 470 nm, 565 nm, 635 nm *Requires interface code cod. 9001 or 9107...
9026 Cuvette
Dimension:45×12.5×12.5 mmMaterial:plasticQuantity:10pcs in 1 set...
9027 Current probe
Range:DC /AC -1.2A ~ +1.2AResolution:0.6 mACircuit properties:This sensor is insulated from groundMax 5W (0.01 W) *Requires interface code cod. 9001 or 9107...
9028 Galvanometer
Range:DC– 12.5 mA ~ + 12.5 mA– 1.25 mA ~ + 1.25 mA– 0.125 mA ~ + 0.125 mAResolution:6mA, 0.6mA, 0.06mACircuit properties:This sensor is insulated from ground *Requires interface code cod. 9001 or 9107...
9029 Differential voltage probe
Input voltage range:– 12.0V ~ + 12.0VInput impedance (to ground):10mWLinearity:0.01%Resolution:3.1 mVSupply voltage:5V DCSupply current (typical):9 mAOutput voltage range:0 V ~ 5 V *Requires interface code cod. 9001 or 9107...
9030 Dissolved oxygen probe
Range:0 mg/L ~ 15 mg/L (or ppm)Accuracy:0.3 mg/LResolution:0.004 mg/LResponse time:95% in 30 secondi98% in 45 secondiTemperature compensation:automatic at 5°C ~ 35°C *Requires interface code cod. 9001 or 9107...
9031 EKG Set
EKGRange:0 mV ~ 5 mVResolution:5mV PULSENumber of pulse:47 bpm ~ 250 bpmResolution:1 bpm *Requires interface code cod. 9001 or 9107...
9032 Dual range force sensor II
Range:– 10 N ~ + 10 N– 80 N ~ + 80 NResolution:0.0056 N0.056 NSensor type: electrical strain gage *Requires interface code cod. 9001 or 9107...
9033 Gas pressure sensor (A)
Range:– 1000 hPa ~ + 3000 hPaResolution:1.3 hPaUnit:Differential relative pressureResponse time:Average 0.2 ms *Requires interface code cod. 9001 or 9107...
Toplam: 68 - Gösterilen sonuçlar: 1 - 20 arası, Sayfa:
1
2
3
4